RV Roof TPO Replacement with Structural Repair on 20’ RV in Tampa, FL
RV Roof Repair in Tampa, FL
RV
20 ft
Damage type
Severe roof damage including compromised membrane, insulation, and structural components
Material
TPO membrane, plywood, insulation, structural joists, primer, sealant
Repair time
4 days
Price
$7075
Work Details
Inspected the RV roof and identified structural and membrane damage
Removed damaged TPO membrane and deteriorated materials
Reinforced roof structure by replacing 2 joists
Replaced 2 sections of insulation
Installed 6 sections of plywood using overlap method
Prepared roof surface for new membrane installation
Installed new TPO membrane across the roof
Performed stripping along both sides of the RV
Sealed slide-out section with silicone
Reinstalled all roof elements and components
Sealed all seams, edges, and penetrations
Completed final inspection and quality check
The Story
The Problem
The RV roof had extensive damage affecting the membrane, insulation, and structural components, leading to potential leaks and loss of integrity.
The Solution
We rebuilt the damaged sections of the roof structure, replaced insulation and plywood, and installed a new TPO membrane with properly sealed seams and components.
The Result
The RV roof is now fully restored with reinforced structure, new insulation, and a durable TPO system for long-term protection.
We completed a full RV roof restoration in Venice, FL on a 20 ft RV with severe structural and membrane damage. The roof required not only replacement of the TPO membrane but also reinforcement of the underlying structure.
Our team replaced 2 joists, 2 sections of insulation, and installed 6 sections of plywood using the overlap method. A new TPO roofing system was installed, and all seams, edges, and penetrations were sealed. Additional work included side stripping and sealing of the slide-out.
The result is a fully restored RV roof with improved structural integrity, insulation, and long-term protection against leaks.
Before & After
Customer feedback
“Now I Trust It” - Police Officer Testimonial After TPO Roof Replacement in Venice
We completed a TPO roof replacement project in Sacramento, CA on a 23 ft RV with membrane damage and localized plywood deterioration.
Our team removed the damaged roofing materials, replaced 3 sections of plywood decking, prepared the roof surface, and installed a new TPO membrane. All roof components, seams, edges, and penetrations were properly sealed to help prevent future leaks.
The result is a restored RV roof with a clean new TPO system, repaired decking, and long-term protection against moisture and weather exposure.
We completed a silicone coating system project in Orlando, FL on a 22 ft 2017 Winnebago. The roof showed signs of aging, worn sealant, and damaged termination bars that needed replacement to improve roof edge protection.
Our team removed the damaged termination bars, installed 2 new termination bars, cleaned and prepared the roof surface, applied primer, and installed a silicone coating system across the roof. All seams, edges, and roof penetrations were sealed to help prevent future leaks.
The result is a restored Winnebago roof with improved protection, clean sealed edges, and a durable silicone coating system designed for long-term weather resistance.
Price: $2800
Read more